| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| ABHP | OVERALL LENGTH | 62.86 MILLIMETERS MINIMUM AND 63.62 MILLIMETERS MAXIMUM |
| ABKW | OVERALL HEIGHT | 82.89 MILLIMETERS MINIMUM AND 86.95 MILLIMETERS MAXIMUM |
| ABMK | OVERALL WIDTH | 57.53 MILLIMETERS MAXIMUM |
| ADAQ | BODY LENGTH | 62.86 MILLIMETERS MINIMUM AND 63.62 MILLIMETERS MAXIMUM |
| ADAT | BODY WIDTH | 57.53 MILLIMETERS MAXIMUM |
| ADAU | BODY HEIGHT | 50.02 MILLIMETERS MINIMUM AND 51.54 MILLIMETERS MAXIMUM |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 18.67 MILLIMETERS MINIMUM AND 19.43 MILLIMETERS MAXIMUM |
| AEGJ | SWITCH CONTACT ARRANGEMENT | DOUBLE POLE, SINGLE THROW, NORMALLY OPEN AND DOUBLE POLE, DOUBLE THROW |
| AGAV | END ITEM IDENTIFICATION | RADAR M/BA |
| AJEC | BOSS HEIGHT | 3.18 MILLIMETERS MINIMUM AND 3.94 MILLIMETERS MAXIMUM |
| AKPX | POLE QUANTITY | 3 |
| CBBL | FEATURES PROVIDED | ROHS DIRECTIVE COMPLIANCE AND TRIP INDICATOR |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 277.0 AC AND 480.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 15.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CPRK | AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 277.0 AC MINIMUM AND 480.0 AC MAXIMUM ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP ALL LOCATIONS |
| CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS ALL LOCATIONS |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 6.0 MINIMUM AT 150 PCT AND 60.0 MAXIMUM AT 150 PCT ALL LOCATIONS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANT AND SALT SPRAY PROOF |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 CELSIUS NOMINAL ALL LOCATIONS |
| CRTK | SWITCH TERMINAL TYPE | SCREW AND QUICK DISCONNECT, MALE |
| CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 15.0 AC |
| CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 277.0 AC AND 480.0 AC |
| CTJS | UNPACKAGED UNIT WEIGHT | 270.0 GRAMS NOMINAL |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | HYDRAULIC MAGNETIC CIRCUIT PROTECTOR |
| FEAT | SPECIAL FEATURES | ONE HANDLE PER POLE. STUD TERMINALS. THREE POLES. AUXILIARY SWITCH, 0.110 QUICK CONNECT, AUXILIARY CONNECTORS REVERSED. 50/60 HZ LONG DELAY. 15 AMP. METRIC THREAD MOUNTING INSERTS AND TERMINALS. 277/480 VAC (50/60 HZ). BLACK. AMBIENT OPERATION TEMPERATURES BETWEEN -40 C TO +85 C. INSULATION RESISTANCE: NOT LESS THAN 100 MEGOHMS AT 500 VOLTS DC. MOISTURE RESISTANCE: MEET ALL THE REQUIREMENTS OF MIL-PRF-55629 WHEN TESTED IN ACCORDANCE WITH METHOD 106 OF MIL-STD-202. SHOCK: CIRCUIT PROTECTORS SHALL NOT TRIP WHEN TESTED PER MIL-STD-202, METHOD 213, TEST CONDITION I WITH 100 PCT RATED CURRENT APPLIED TO DELAYED UNITS AND 80 PCT RATED CURRENT TO INSTANTANEOUS UNITS. VIBRATION: CIRCUIT PROTECTORS SHALL NOT TRIP WHEN VIBRATED PER MIL-STD-202, METHOD 204, TEST CONDITION A WITH 100 PCT RATED CURRENT APPLIED TO DELAYED UNITS AND 80 PCT RATED CURRENT TO INSTANTANEOUS UNITS. |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| MATT | MATERIAL | PLASTIC CASE |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW AND 3 QUICK DISCONNECT, MALE |