| ABHP | OVERALL LENGTH | INCHES MAXIMUM 3.640 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES MINIMUM 2.990 AND INCHES MAXIMUM 3.010 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 4.595 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 3.315 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.266 |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS NOMINAL 64.5 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY UNTHREADED HOLE(S) 2 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | CUBIC MEASURE | CUBIC INCHES 55.445 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY IN-LINE |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION 1 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES DC 500.0 |
| CRXH | TIME DELAY | FIXED OPERATE TIME SECONDS MAXIMUM 0.025 |
| CRXH | TIME DELAY | FIXED RELEASE TIME SECONDS MAXIMUM 0.01 |
| CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION 1 AND POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION 1 |
| CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 28.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD AMPERES DC 100.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD AMPERES AC 50.0 AND AMPERES DC 50.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | MOTOR LOAD AMPERES AC 75.0 AND AMPERES DC 100.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 100.0 AND AMPERES DC 100.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD AMPERES AC 5.0 AND AMPERES DC 5.0 |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD MILLIAMPERES AC 750.0 AND MILLIAMPERES DC 750.0 |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 5.0 AND AMPERES DC 5.0 |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-6106 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS THREADED STUD 8 |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT STANDARD 96906--S24141 |